You are here:    Home » Products » Design & Installation

Technical

Roof Drainage Design

Design Basis

Alutec gutter flow capacities shown overleaf in the flow capacity table and are calculated with the gutters being fixed nominally level. Most metal gutters are installed level for aesthetic purposes. However, if installed to a fall of 1:600 the flow capacity will be marginally improved.

Factors to be considered when designing an eaves drainage system.

  1. Rainfall Intensity design rate (l/s/m2).
  2. Effective Roof Area (ERA) to be drained (m2).
  3. Gutter flow capacity (l/s).
  4. Size, number and position of outlets.
  5. Frictional resistances in long gutter runs and the number of corners.
Click here for more information