Detailed installation instructions are supplied with each consignment. Also available on request.

1. Fix fascia brackets at 1 metre centres, nominally level or fall of 1:600.

2. Position outlets and angles and fix using 32mm x No 10 Countersunk Screws Code SC202.

3. Ensure that the factory fitted rubber spacers are attached to the inside of the union. Apply 2 Nr 8mm dia beads of sealant to each side of the union. Do not carry out jointing in wet weather or temperatures below 5ºC or above 40ºC.

4. Fit gutter into fascia brackets by first inserting the rear up stand, then snapping down the front. Repeat sequence 6, 7 & 8 to the next gutter length and joint the gutter lengths together.

5. Anchor each joint union by slightly pulling the gutter ends apart and inserting a 32mm x No 10 Countersunk Screw into the fascia via the hole provided.

6. Push gutter ends together to close joint gap leaving a minimum 3mm expansion gap. Point sealant into gap.
NB: Jointing should not be carried out in wet weather, temperatures below 5°C or above 40°C