Shower Applications
Alutec Shower Outlet Typical Applications

Horizontal Spigot Shower Outlet - Flexible sheet flooring on timber deck
- Fix floor boarding with fall towards outlet. Cut 170mm dia. hole with 5mm deep x 15mm wide flange recess.
- Place outlet body into hole ensuring outer flange is flush with floor surface.
- Connect waste pipe to outlet.
- Lay and adhere flexible sheet flooring over outlet body then carefully cut a 115mm dia hole central to the outlet.
- Secure clamping ring with screws provided, ensuring sheet flooring is positively clamped and compressed into shower outlet body.
- Position and secure grate/removable trap cover.

Vertical Spigot Shower Outlet - Tiled flooring on concrete deck
- Grout outlet body into hole within slab, ensuring that flange is set at lowest screed level.
- Lay screed to correct falls to finish level with outlet flange.
- Lay waterproofing membrane over screeded finish floor and outlet body Carefully cut a 115mm dia. hole central to outlet.

- Secure clamping ring with screws provided ensuring waterproofing membrane is positively clamped and secured to the outlet body.
- Position tile set grate centrally over outlet body and commence laying tiles outwards to complete area.
- Position and secure special removable trap.
- Secure grate into tile set surround.